JSI
WeldPASS-II Resistance Spot Welding Process Monitor
The
system uses 7 channels for monitoring current, voltage, displacement
X 2, force X 2, and argon flow rate. More channels are available
for future use.
Hardware
features:
16 bit high accuracy
Analog-to-Digital conversion.
High speed 500k samples/second/channel
data acquisition.
Digital I/O for communication
with automated welder or other equipments.
Flexible sensor selection.
Ethernet and RS232
communication ports available.
Software
Features:
3 levels (Operator,
Engineer and Calibration) secure configuration access
administration.
Advanced zero-phase
shift digital filtering technique is utilized.
Record waveforms and
measurement data for every weld.
Run charts for all measurement data.
Waveforms are indexed
in log file.
Accepts user Transfer Function input.
Limit control and
out-of-limit alarm for every weld.
Source code of communication
client software available for customer to tailor customized
communication interface to corporate database.